Short answer: CBSE asks for one Composite Skill Lab of at least 600 sq ft (Classes VI–XII) or two of at least 400 sq ft. Its suggested specifications are for a 30 x 20 ft room: group work tables (5 x 4 or 6 x 4 ft), stackable stools, lockable steel cupboards, 4 x 3 ft tool pegboards, open shelves, a safety rack, a sink platform where needed and a digital display, on concrete or rubber flooring with 15A and 5A sockets.
By the Amica Smart Learn team · Updated 29 November 2026 · Based on CBSE Circular Skill-13/2026 and CBSE's Composite Skill Lab guidelines

A skill lab fails when tools are locked away and nobody can find them, or when 40 students crowd one table. The CBSE booklet spends a surprising amount of space on furniture and layout for exactly this reason. Here is the practical version.
| Option | Area | Use |
|---|---|---|
| One lab | 600 sq ft minimum | Classes VI–XII |
| Two labs | 400 sq ft minimum each | One for VI–X, one for XI–XII |
CBSE's model layouts show both sizes. In a 400 sq ft room, plan two or three group tables and wall storage; in 600 sq ft, four to five tables with sector zones.
| Element | CBSE suggested specification |
|---|---|
| Working tables | Sturdy wooden top, rounded edges, 5 x 4 ft or 6 x 4 ft |
| Stools | 12 x 12 x 20 inch, perforated top, powder-coated steel frame, rubber levellers |
| Wall storage cupboards | Steel, 4 adjustable shelves, lock, about 78 x 36 x 24 inch |
| Teacher's cupboard | Steel, 3 shelves, lock, about 48 x 36 x 18 inch |
| Teacher's desk | Wooden, 3 x 2 ft |
| Tool pegboards | 4 x 3 ft, 18 mm waterproof ISI plywood |
| Open shelves | About 2 ft high and 2 ft deep along the wall |
| Safety rack | 48 x 48 x 18 inch iron rack; extinguisher and 2 sand buckets on the wall |
| Sink | About 37 x 18 x 8 inch on a 4 x 3 ft platform |
| Display | LED TV or screen and projector |
We plan the layout and install the furniture and tools: CBSE Composite Skill Lab setup.
Setting up your Composite Skill Lab?
Call or WhatsApp +91 91251 61262 for a room plan, equipment list for your chosen sectors and a written quote. We supply, install and train across India.
600 sq ft for one lab serving Classes VI–XII, or two labs of 400 sq ft each.
Concrete flooring or rubber mats; CBSE advises avoiding vitrified tiles or stone.
A combination of 15-ampere and 5-ampere sockets, preferably on all walls.
Only if the chosen subjects need flowing water regularly, such as food production or beauty; it is optional for others.